Table 3 Summary of the studies and technological implementation of Wartenberg’s pendulum test

From: Objective assessment of spasticity by pendulum test: a systematic review on methods of implementation and outcome measures

Author/year

joint

People under study (number of participants)

Main technology

Compared to clinical scale

Couvée, 1968 [52]

Knee

Paraplegia (N = 6)

Healthy (N  = 5)

Potentiometer

NC

Bajd, 1984 [38]

Knee

SCI (N = 10)

Hemiplegics (N = 5)

Electro goniometer

Tachometer

NC

Leslie, 1992 [42]

Knee

MS (N = 14)

Electro goniometer

AS

Stillman, 1995 [19]

Knee

Healthy young, middle aged, elderly (N = 77)

Video camera

NC

He, 1997 [44]

Knee

MS (N = 46)

Electro goniometer

NC

Kaeser, 1998 [34]

Knee

Healthy (N = 40)

Spastic (N = 9)

Electro goniometer

Ultrasound

AS

Greenan Fowler, 2000 [6]

Knee

CP (N = 30)

Healthy (N = 10)

Electro goniometer

MAS

Cavorzin, 2001 [53]

Knee

Spastic (N = 15)

Healthy (N = 10)

Potentiometer

EMG

AS

Nordmark, 2002 [17]

Knee

CP (SDR) (N = 20)

Electro goniometer

EMG

MAS

Lin, 2003 [47]

Elbow

Stroke (N = 11)

Healthy (N = 11)

Electro goniometer

EMG

AS

Syczewska,2009 [29]

Knee

CP (N = 21)

Trauma (N = 6), DS (N = 3)

Vicon Motion Capture

ENG

NC

Bohannon, 2009 [46]

Knee

Chronic stroke (N = 8)

Polhemus Liberty magnetic position tracking system

AS

Sterpi, 2013 [18]

Knee

Severe cerebral lesion (N = 11)

healthy (N = 10)

Inertial sensor (Accelerometer, Gyroscope, Magnetometer)

MAS

Tancredo, 2013 [31]

Knee

SCI (N = 11)

Accelerometer, Electro goniometer

MAS

Lemoyne, 2013 [54]

Ankle

Healthy (N = 1)

Accelerometer (IPhone wireless)

NC

Azevedo, 2013 [55]

Knee

SCI (N = 5) (5 Time)

Electro goniometer

NC

Szopa, 2014 [43]

Knee

CP (N = 36)

Healthy (N = 18)

Accelerometer

DAROM

Yeh, 2016 [45]

Knee

Stroke (N = 13)

Healthy (N = 3)

Electro goniometer (Two)

Gyroscope (Wii remote)

MAS

Vargas Luna, 2016 [41]

Knee

SCI (N = 4)

Goniometer

Video tracking

AIS

Bui, 2017 [40]

Knee

ARSACS (N = 13)

Healthy (N = 32)

Gyroscope

Accelerometer

MAS

Popovic-Maneski, 2017 [37]

Knee

Chronic SCI (N = 2)

Healthy (N = 5)

Accelerometers (two)

Gyroscope

Encoder (Hall-effect)

EMG

MAS

Popovic-Maneski, 2018 [39]

Knee

SCI (N = 9)

Healthy (N = 6)

Absolute joint angle

encoder

Gyroscope

EMG Electrode

AS

Aleksić, 2018 [39]

Knee

SCI (N = 1)

Healthy (N = 1)

Marker-based system

Joint angle encoder and IMU

NC

Popović, 2018 [56]

Knee

CNS lesion (N = 0)

Accelerometers (two)

Gyroscope

Encoder (Hall-effect)

EMG

AS

Whelan, 2018 [36]

Knee

ABI (N = 45)

MS (N = 14)

CP (N = 12)

SCI (N = 22)

Fiber-optic goniometer (FOG)

EMG electrode