Skip to main content

Table 2 RMSE of MLE algorithm for synthetic signals with CV equal to 3, 4, and 5 m/s, force level equal to 20, 40 and 60 % of the MVC and SNR of \(\infty \) (noise free), 30, 20, 16 and 12 dB

From: Motor unit action potential conduction velocity estimated from surface electromyographic signals using image processing techniques

CV (m/s)

\(\infty \) dB SNR

30 dB SNR

20 dB SNR

16 dB SNR

12 dB SNR

Force level = 20% MVC

 3

0.03

0.03

0.04

0.04

0.15

 4

0.04

0.04

0.04

0.04

0.12

 5

0.05

0.05

0.05

0.06

0.15

Force level = 40% MVC

 3

0.03

0.03

0.03

0.04

0.13

 4

0.04

0.04

0.04

0.05

0.24

 5

0.04

0.04

0.04

0.06

0.08

Force level = 60% MVC

 3

0.03

0.03

0.03

0.04

0.16

 4

0.04

0.04

0.04

0.04

0.08

 5

0.04

0.05

0.05

0.06

0.09