Skip to main content
Figure 8 | BioMedical Engineering OnLine

Figure 8

From: Atrial fibrillation detection by heart rate variability in Poincare plot

Figure 8

Flow chart to discriminate AFib from non-AFib. We tried to discriminate AFib from non-AFib using three feature measures. We divided the distribution of the number of clusters into two, and calculated the lower mean value by k-means clustering method. We decided there was a pattern in Poincaré plot if the number of clusters of a test data is more than one and less than this mean value. Otherwise we further applied support vector machine method to the other remaining features measures.

Back to article page