Skip to main content

Table 2 Statistical results of this method for three testing databases (at the threshold of 0.353)

From: Automatic online detection of atrial fibrillation based on symbolic dynamics and Shannon entropy

Method

Features

Year

Database

Key techniques

Results

     

Se(%)

Sp(%)

PPV(%)

ACC(%)

This method

RRI

2013

AFDB

 

96.89

98.25

97.62

97.67

   

AFDB

Nonlinear

96.82

98.06

97.61

97.50

   

AFDB

filter + integer

97.83

98.19

97.56

98.04

   

MITDB

filters + symbolic

97.33

90.78

55.29

91.46

   

NSRDB

dynamics + SE

NA

98.28

NA

NA

   

AFDB+NSRDB

 

96.89

98.27

92.30

98.03

   

AFDB+NSRDB

 

97.53

98.26

90.09

98.16

  1. Records “00735” and “03665” omitted.
  2. Records “04936” and “05091” omitted.